Teranex

The Teranex needs to be put up-stream of the Pixi in the video path.

The version of Pogle Platinum has to be v521 or greater.

The "/etc/hosts" file will need to have a "teranex-server" entry; for example:

Example /etc/hosts


First, in the "room-setup" panel you must set the noise reducer type to NONE:

No noise reducer


Next, enable the Teranex in the same panel:

Teranex


Now the Teranex front panel LCD display will change to show the unit is being controlled remotely. You can now load the "Teranex" panel (in the Vault) to control the noise reducer:

Teranex


Now click on any numerical function and it will be mapped to an encoder on the Blue/Amber display.

Notes

If you do not have an Ethernet controlled Pixi attached to your system then you will need to temporarily change your SCC Type to "Pixi/MegaDef" in the "room-setup" panel and save the new configuration by closing the panel.  Now, change the Control from "RS422" to "Ethernet" in the "SCC-Setup" panel.  Close "SCC-Setup" to save this new setting, then re-open the "room-setup" and change back the SCC Type to your current manufacturer.  Note: failure to do this will disable encoder control of the Teranex from the blue/Amber display, although the function name will still be seen/mapped underneath the encoder.

Please note that Teranex settings can be programmed but currently it is not possible to perform single frame Teranex corrections or create a dynamic between two Teranex settings. Event duration must be a MINIMUM of 3 frames. This is a known problem with the Teranex software itself.