Telecine Primary control


The telecine primary controls are available when the top two balls are green. If they are not green, press and hold the left button above the lower ball until they turn green. When green, the top left ball controls lift and the top right controls gain. If the lower ball is green then the telecine gamma is controlled.


If remote PEC control is available then a short press on the same button will turn only the lower ball red, allowing PEC control. A short press of the same button will toggle between PEC and gamma control. Telecine lift and gain are available in either mode.

Telecine Six Vector Secondary (for MKIII and URSA)

Telecine six vector secondary and DCP 1 six vector secondary are available by pressing the 1 key on the DCP panel. In the DCP 1 panel, there is a button to switch between DCP and RANK. Only one of these two secondaries can be programmed into an event.

Six fixed vectors exist for the Rank secondary, these are selected using the R, G, B, Y, C and M keys. The hue, saturation and luminance within the selected vector can be adjusted using the three controls on the upper left hand side of the DCP panel.