If the corrections are occurring on the wrong field, then change the value in the FIELD box to either 1 or 0. Do not set this value to anything other than 1 or 0.
If the colour corrections are happening late, determine how many frames and increase the O/P FWD value by that number.
If the colour corrections are happening early, determine how many frames and decrease the O/P FWD value by that number.
Repeat the above steps until the grading changes are happening at the correct time.
Repeat the process for the noise reducer, adjusting the values that on the NOISE REDUCER line of the Room setup panel. Instead of making a change on the secondary colour corrector, make the change on the noise reducer. An obvious grading change is contour or aperture value.
Do not worry about changing these values in the Room Setup panel,
they will not affect the values that have been set for Film To Tape.
Once set the Platinum will automatically recall the correct setting
for each mode.